Fire Protection Engineering for Facilities UFC 3-600-01 - US

Read or Download Fire Protection Engineering for Facilities UFC 3-600-01 - US DOD PDF

Best engineering books

Trends in Computer Science, Engineering and Information Technology: First International Conference on Computer Science, Engineering and Information Technology, CCSEIT 2011, Tirunelveli, Tamil Nadu, India, September 23-25, 2011. Proceedings

This e-book constitutes the refereed complaints of the 1st overseas convention on desktop technology, Engineering and knowledge know-how, CCSEIT 2011, held in Tirunelveli, India, in September 2011. The seventy three revised complete papers have been rigorously reviewed and chosen from greater than four hundred preliminary submissions.

Strategies and Applications in Quantum Chemistry: From Molecular Astrophysics to Molecular Engineering

On the time while expanding numbers of chemists are being attracted by means of the fascination of supposedly effortless computing and linked vibrant imaging, this e-book appears to be like as a counterpoint. the 1st half specializes in primary thoughts of quantum chemistry, protecting MCSCF thought, perturbation remedies, foundation set advancements, density matrices, wave functionality instabilities to correlation results, and momentum area thought.

Extra resources for Fire Protection Engineering for Facilities UFC 3-600-01 - US DOD

Sample text

2 Locking Devices. Provide mechanical or closed circuit electrical gang release devices whenever 10 or more locks must be operated to release prisoners confined in cells. Require gang release devices to open doors necessary to evacuate prisoners to an area of refuge. Require heavy, identically keyed, prison-type locks for exit and corridor doors not requiring gang release devices that must be opened for evacuation in the event of fire. Exception: Dormitory-style confinement facilities. 3 Interior Finish.

Warehouse fire areas may be increased to 11,148 m2 (120,000 ft2) with the following provisions: • Ceiling sprinkler design area must be increased by 10 percent. ESFR sprinklers must increase the required number to be calculated by 10 percent. • Looped mains with adequate sectional valves must be provided around the facility. 49 UFC 3-600-01 17 April 2003 with change 16 January 2004 • A secondary fire pump must be provided when a fire pump is provided. 5 Fire Walls. Firewalls separating warehouse and storage fire areas must be of 4-hour fire rated construction.

Exception: A diesel driven fire pump does not have to be provided when the fire pump is equipped with an automatic transfer switch and connected to an emergency generator. 5 Water Level Controls. Manual controls, double-acting altitude valves, or other automatic devices must be used to maintain the water level in elevated storage tanks. Altitude valves must be arranged with bypasses. 6 Meters. Where meters are installed on fire sprinkler and hose stream water distribution systems, they must be listed by an NRTL as fire flow meters.